Electra OU7-24 RC Manual de Serviço Página 39

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 38
5-22
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02 Service Manual - KN Series
5.15.2 Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15 20 25
ENTERING AIR
WB OU COIL ( °C)
TH PI TH PI TH PI
-10 6.93 3.70 6.67 3.94 6.40 4.14
-7 7.46 3.80 7.19 4.00 6.93 4.22
-2 7.92 3.84 7.66 4.07 7.39 4.31
2 9.64 4.03
9.24 4.28
8.84 4.54
6 13.60 4.33 13.20 4.63 12.74 4.92
10 14.78 4.57
14.39 4.88
13.99 5.22
15 15.97 4.77 15.58 5.14 15.18 5.46
20 16.83 4.91 16.43 5.32 15.97 5.74
* the above chart includes the weighted deicing infleuence.
LEGEND
TH Total Heating Capacity, kW
PI Power Input, kW
WB Wet Bulb Temp., (
o
C)
DB Dry Bulb Temp., (
o
C)
ID Indoor
OU Outdoor
5.16 Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m 15m 20m 25m 30m 40m 50m
1.01
1
0.98 0.97 0.96 0.95 0.94 0.93 0.90
* Minimum recommended tubing length between indoor and outdoor units is 4m.
5.16.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m 15m 20m 25m 30m 40m 50m
1.02
1
0.99 0.99 0.98 0.97 0.97 0.96 0.95
* Minimum recommended tubing length between indoor and outdoor units is 4m.