PERFORMANCE DATA & PRESSURE CURVES
5-13SM SX Ser1-A.3 GB
5.10 SX 18 / GC18 R410A
5.10.1 Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
DATA
ENTERING AIR WB/DB ID COIL ( °C)
15/21 17/24 19/27 21/29 23/32
15
(1)
TC
5.80 6.00 6.15 6.29 6.39
SC
3.94 4.11 4.27 4.37 4.45
PI
1.29 1.29 1.30 1.30 1.31
20
(1)
TC
5.61 5.91 6.10 6.24 6.38
SC
3.86 4.07 4.24 4.36 4.44
PI
1.40 1.41 1.41 1.42 1.42
25
TC
5.31 5.73 6.02 6.21 6.36
SC
3.76 3.99 4.21 4.33 4.41
PI
1.51 1.52 1.53 1.54 1.56
30
TC
4.96 5.40 5.84 6.05 6.22
SC
3.64 3.87 4.11 4.24 4.32
PI
1.63 1.66
1.67
1.68 1.70
35
TC
4.59 4.99
5.50
5.78 6.05
SC
3.46 3.71 4.02 4.14 4.22
PI
1.76 1.79
1.82
1.83 1.84
40
TC
4.18 4.55
4.96
5.43 5.71
SC
3.26 3.51 3.80 3.92 4.00
PI
1.90 1.93 1.96 1.99 2.01
46
TC
3.62 3.96 4.36 4.82 5.19
SC
3.01 3.22 3.47 3.59 3.67
PI
2.08 2.11 2.16 2.19 2.21
LEGEND
TC Total Cooling Capacity, kW
SC – Sensible Capacity, kW
PI Power Input, kW
WB Wet Bulb Temp., (
o
C)
DB Dry Bulb Temp., (
o
C)
ID Indoor
OU Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).