PERFORMANCE DATA & PRESSURE CURVES
5-25SM SX Ser1-A.3 GB
5.19 SX 30 / OU8- 30 R410A
5.19.1 Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OU COIL (°C)
DATA
ENTERING AIR WB/DB ID COIL ( °C)
15/21 17/24 19/27 21/29 23/32
15
(1)
TC
8.98 9.30 9.52 9.75 9.89
SC
5.68 5.92 6.15 6.31 6.42
PI
2.12 2.12 2.13 2.13 2.14
20
(1)
TC
8.69 9.16 9.45 9.67 9.88
SC
5.57 5.87 6.12 6.29 6.41
PI
2.30 2.31 2.32 2.33 2.33
25
TC
8.22 8.88 9.33 9.61 9.85
SC
5.42 5.76 6.07 6.24 6.36
PI
2.49 2.50 2.52 2.54 2.55
30
TC
7.69 8.37 9.04 9.36 9.64
SC
5.25 5.58 5.94 6.11 6.23
PI
2.68 2.72
2.75
2.77 2.79
35
TC
7.12 7.72
8.52
8.95 9.37
SC
5.00 5.36 5.80 5.97 6.08
PI
2.89 2.94
2.99
3.01 3.03
40
TC
6.47 7.05
7.69
8.41 8.84
SC
4.71 5.07 5.49 5.66 5.78
PI
3.12 3.17 3.22 3.26 3.30
46
TC
5.62 6.14 6.75 7.46 8.04
SC
4.34 4.65 5.00 5.18 5.29
PI
3.41 3.46 3.54 3.59 3.63
LEGEND
TC Total Cooling Capacity, kW
SC – Sensible Capacity, kW
PI Power Input, kW
WB Wet Bulb Temp., (
o
C)
DB Dry Bulb Temp., (
o
C)
ID Indoor
OU Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).