PRODUCT DATA SHEET
2-1SM SX Ser1-A.3 GB
2. PRODUCT DATA SHEET
2.1 SX 9 / ONG-9 R410A
Model Indoor Unit SX-9
Model Outdoor Unit ONG-9
Installation Method of Pipe Flared
Characteristics Units Cooling Only Cooling Heating
Capacity
(1)
Btu/hr 9080 9080 9520
kW 2.66 2.66 2.79
Power input
(1)
kW 0.825 0.825 0.86
EER (Cooling) or COP(Heating)
(1)
W/W 3.22 3.22 3.24
Energy efficiency class A A C
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 3.7 3.7 4.0
Starting current A 18.7
Circuit breaker rating A 10
INDOOR
Fan type & quantity Centrifugal x 2
Fan speeds H/M/L RPM 740/650/600
Air flow
(2)
H/M/L m3/hr 370/330/290
External static pressure Min-Max Pa 0
Sound power level
(3)
H/M/L dB(A) 50/49/47
Sound pressure level
(4)
H/M/L dB(A) 39/37/35
Moisture removal l/hr 1.1
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 820x630x190
Weight kg 21
Package dimensions WxHxD mm 890x710x280
Packaged weight kg 25
Units per pallet units 14
Stacking height units 7 levels
OUTDOOR
Refrigerant control Capillary tube
Compressor type, model Rotary,LG GK113PAG
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 780
Air flow H/L m3/hr 1780
Sound power level H/L dB(A) 58 60
Sound pressure level
(4)
H/L dB(A) 48 49
Dimensions WxHxD mm 795x610x290
Weight kg 34 35
Package dimensions WxHxD mm 945x655x395
Packaged weight kg 38 39
Units per pallet Units 9
Stacking height units 3 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 1kg/7.5m
Additional charge per 1 meter g/m 7.5m<Lin<15m:+10g/m
Connections between units
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 3/8"(9.53)
Max. tubing length m. Max.15
Max. height difference m. Max.7
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.