CONTROL SYSTEM
11-1SM SX Ser1-A.3 GB
11. CONTROL SYSTEM
11.1 Electronic Control
11.1.1 Introduction
The electronic control information is designed for service applications, and is common
to the following groups of air-conditioners:
ST/RC group -Cooling only / cooling and heating by heat pump.
SH group -Cooling and heating by heat pump and supplementary
heater.
RH group -Cooling, heating by heaters only.
11.1.2 Model Plug Settings
Before installation, make sure to set the model plug conforming to the suitable group.
GROUP
J6 Setting J2 Setting
ST / RC Open Open
SH Closed Open
RH Closed Closed
Model Plug